Tanya via WhatsApp

Tenmars TM-196 3 – Axis RF Field Strength Meter

Share on facebook
Share on twitter
Share on linkedin
Tenmars TM-196 3 - Axis RF Field Strength Meter

Tenmars TM-196 3 – Axis RF Field Strength Meter

Meteran ini dirancang untuk mengukur dan memantau kekuatan medan elektromagnetik Frekuensi Radio. Meter dikalibrasi dengan tepat pada rentang frekuensi 10MHz~8GHZ.

  • Rentang pengukuran: 38mV hingga 11V/m
  • Rentang frekuensi: 10MHz ~ 8GHZ.
  • Sensor: Sumbu Tiga (X, Y, Z).
  • Catatan memori data manual (Maks & AVG).

Produk asli Kami distributor langsung Tenmars. Harga murah. Pengiriman ke seluruh Indonesia.


Layanan Pelanggan
0813-1864-0412, 0813-9895-5475
Email : [email protected]

Tenmars TM-196 3 – Axis RF Field Strength Meter

TM-196 is designed for measuring and monitoring Radio Frequency(RF) electromagnetic field strength and capable of measuring the frequency range of 10Mz~8GHz. It’s ideal for the applications of:

  • RF power measurement for transmitters.
  • High frequency(RF)electromagnetic wave field strength measurement.
  • Mobile phone base station antenna radiation power density measurement.
  • Spy camera, wireless bug finder.
  • Wireless communication (CW, TDMA, GSM, DECT) applications.
  • Wireless LAN (Wi-Fi) detection, installation.
  • Cellular /Cordless phone radiation safety level.
  • Microwave oven leakage detection.
  • Personal living environment EMF safety.

Features Tenmars TM-196 3 – Axis RF Field Strength Meter :

  • Measurement range: 38mV to 11V/m
  • Frequency range: 10MHz~8GHZ.
  • Sensor: Triple Axis (X, Y, Z).
  • Manual data memory (Max & AVG) records.
  • Calibration factor, Alarm and Clock settings.

Specifications Tenmars TM-196 3 – Axis RF Field Strength Meter :

Measurement range
 50mV/m to 11V/m
 Display
 4½ digits maximum reading 19999
 Frequency range
 10MHz~8GHz
 (accuracy :±1dB at 2.45GHz)
 Measurement units
 mV/m, V/m, µA/m, mA/m,
 µW/m², mW/m²,µW/cm²
 Display resolution
 0.1mV/m, 0.01V/m,
0.1µA/m, 0.001mA/m,
 0.001µW/m², 0.01mW/m²,
0.001µW/cm²
 Manual data memory
 200 data sets
 Alarm function
 Adjustable threshold with ON/OFF
 Memory recall
 Adjustable
 Calibration factor CAL
 The CAL setting range is from 0.10~5
 Sampling time
 3 times per second
 Operating temperature
 and humidity
 0°C~50°C (32°F~122°F),
 25% ~75% RH
 Power supply
 9V battery
(NEDA 1604 IEC 6F22 JIS 006P)
 Battery life
 Approx. 3hours
 Dimension
 370x80x80mm (LxWxH)
 Weight
 Approx.400g (including battery)

 


  TM-196  En User’s Manual


Produk asli Kami distributor langsung Tenmars. Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya Indonesia.

Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.

 

CEK JUGA YANG INI

BUAT PERMINTAAN HARGA