Tanya via WhatsApp

Lutron DW-6090A Power Analyzer

Share on facebook
Share on twitter
Share on linkedin
Lutron DW-6090A Power Analyzer

Lutron DW-6090A Power Analyzer

  • Watt, VA, Faktor daya, ACV, ACA, DCV, DCA,
  • VAr, Whr, ohm, rms sebenarnya untuk Watt, ACV, ACA
  • Resolusi 0,1 Watt untuk pengukuran daya rendah

OHMS

  • Akurasi Resolusi Rentang
  • 9,999 ohm 1 ohm ( 1 % + 1d )
  • 19,99 K ohm 10 ohm

 


Produk asli Kami distributor langsung Lutron Harga murah. Pengiriman ke seluruh Indonesia.


Whatsapp :  0851 6306 9421
Email : [email protected]

 

Lutron DW-6090A Power Analyzer

CV. Syariftama Multi Global has a wide range of Lutron products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

Specifications Lutron DW-6090A Power Analyzer :

  • Watt, VA, Power factor, ACV, ACA, DCV, DCA,
  • VAr, Whr, ohms, true rms for Watt, ACV, ACA
  • 0.1 Watt resolution for low power measurement

OHMS

  • Range Resolution Accuracy
  • 9,999 ohm 1 ohm ( 1 % + 1d )
  • 19.99 K ohm 10 ohm

Watt (AC, true power)

  • current mode from direct input
  • Range Resolution Accuracy
  • 6,000 Watt 0.1 W (< 1000W ) ( 1.5% + 5 d )
  • 1 W ( ‘ 1000W )

Watt (AC, true power)

  • current input cooperate with inductive probe or CT
  • Range Resolution
  • 0.1 to 999,9 Watt 0.1 Watt
  • 9,999 Watt 1 Watt
  • 99.99 KW 0.01 KW
  • 999.9 KW 0.1 kW

VA ( AC, Apparent Power )

  • current mode from direct input
  • Range Resolution Accuracy
  • 99.99 VA 0.01 VA ( 2 % + 2d )
  • 999.9 VA 0.1 VA
  • 9,999 VA 1 VA

Power Factor

  • current mode from direct input only
  • Range Resolution Accuracy
  • 0.01 to 1.00 0.01 ( 1.5% + 2 d )

Hz

  • Range Resolution Accuracy
  • 10.0 Hz to 99.9 Hz. 0.1 Hz ( 1 % + 1d )
  • 100 Hz to 999 Hz. 1 Hz

Ac Voltage ( true rms ), Dc Voltage

  • Range Resolution Accuracy
  • 0.1 V to 299.9 V 0.1 V DCV : ( 1 % + 1d )
  • 300 V to 600 V 1 V ACV ( 1( 10 V ) : ( 1 % + 7d )
  • ACV ( 1( 11 V to 100 V ) : ( 1 % + 5d )
  • ACV ( O ( Others ) : ( 1 % + 1d )

Ac Current ( true rms ), Dc Current

  • current mode from direct input
  • Range Resolution Accuracy
  • ACA 0.05 A to 1.999 A 1 mA (1%+3d)
  • 2.00 A to 10.00 A 10 mA
  • DCA 0.01 A to 10.00 A 10 mA (1%+1d)

Ac Current ( true rms ), Dc Current

  • current mode from inductive probe
  • Range Resolution
  • ACA < 2 A 0.01 A
  • 2 A to 1000 A 0.1 A
  • > 1000 A 1 A
  • DCA 1000 A 1 A

Ac Current

  • current mode from CT ( current transformer )
  • Range Resolution
  • CT 100/5A, 0.1 – 200.0 A 0.01 A, < 20 A
  • 0.1 A, ‘ 20 A
  • CT 1000/5A, 1 – 2000 A 0.1 A, , < 20 A
  • 1 A, ‘ 200 A

Standard Accessories : 

  • Test lead merah hitam
  • Instruction Manual
  • Certificate Calibration

Optional produk : 

  • Battery AA (UM-3) 1,5 Volt , 6 Pcs
  • DC Adaptor AP-9VA

 

 


Lutron DW-6090A Datasheet


Produk asli Kami distributor langsung Lutron Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya Indonesia.

Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.

 

CEK JUGA YANG INI

BUAT PERMINTAAN HARGA