Tanya via WhatsApp

Lutron DW-6090A Power Analyzer

Share on facebook
Share on twitter
Share on linkedin
Lutron DW-6090A Power Analyzer

Lutron DW-6090A Power Analyzer

  • Watt, VA, Power factor, ACV, ACA, DCV, DCA,
  • VAr, Whr, ohms, true rms for Watt, ACV, ACA
  • 0.1 Watt resolution for low power measurement

 


Produk asli Kami distributor langsung Lutron Harga murah. Pengiriman ke seluruh Indonesia.


Whatsapp :  0821 3010 0456
Email : [email protected]

 

Lutron DW-6090A Power Analyzer

CV. Syariftama Multi Global has a wide range of Lutron products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

Specifications Lutron DW-6090A Power Analyzer :

  • Watt, VA, Power factor, ACV, ACA, DCV, DCA,
  • VAr, Whr, ohms, true rms for Watt, ACV, ACA
  • 0.1 Watt resolution for low power measurement

OHMS

  • Range Resolution Accuracy
  • 9,999 ohm 1 ohm ( 1 % + 1d )
  • 19.99 K ohm 10 ohm

Watt (AC, true power)

  • current mode from direct input
  • Range Resolution Accuracy
  • 6,000 Watt 0.1 W (< 1000W ) ( 1.5% + 5 d )
  • 1 W ( ‘ 1000W )

Watt (AC, true power)

  • current input cooperate with inductive probe or CT
  • Range Resolution
  • 0.1 to 999,9 Watt 0.1 Watt
  • 9,999 Watt 1 Watt
  • 99.99 KW 0.01 KW
  • 999.9 KW 0.1 kW

VA ( AC, Apparent Power )

  • current mode from direct input
  • Range Resolution Accuracy
  • 99.99 VA 0.01 VA ( 2 % + 2d )
  • 999.9 VA 0.1 VA
  • 9,999 VA 1 VA

Power Factor

  • current mode from direct input only
  • Range Resolution Accuracy
  • 0.01 to 1.00 0.01 ( 1.5% + 2 d )

Hz

  • Range Resolution Accuracy
  • 10.0 Hz to 99.9 Hz. 0.1 Hz ( 1 % + 1d )
  • 100 Hz to 999 Hz. 1 Hz

Ac Voltage ( true rms ), Dc Voltage

  • Range Resolution Accuracy
  • 0.1 V to 299.9 V 0.1 V DCV : ( 1 % + 1d )
  • 300 V to 600 V 1 V ACV ( 1( 10 V ) : ( 1 % + 7d )
  • ACV ( 1( 11 V to 100 V ) : ( 1 % + 5d )
  • ACV ( O ( Others ) : ( 1 % + 1d )

Ac Current ( true rms ), Dc Current

  • current mode from direct input
  • Range Resolution Accuracy
  • ACA 0.05 A to 1.999 A 1 mA (1%+3d)
  • 2.00 A to 10.00 A 10 mA
  • DCA 0.01 A to 10.00 A 10 mA (1%+1d)

Ac Current ( true rms ), Dc Current

  • current mode from inductive probe
  • Range Resolution
  • ACA < 2 A 0.01 A
  • 2 A to 1000 A 0.1 A
  • > 1000 A 1 A
  • DCA 1000 A 1 A

Ac Current

  • current mode from CT ( current transformer )
  • Range Resolution
  • CT 100/5A, 0.1 – 200.0 A 0.01 A, < 20 A
  • 0.1 A, ‘ 20 A
  • CT 1000/5A, 1 – 2000 A 0.1 A, , < 20 A
  • 1 A, ‘ 200 A

Standard Accessories : 

  • Test lead merah hitam
  • Instruction Manual
  • Certificate Calibration

Optional produk : 

  • Battery AA (UM-3) 1,5 Volt , 6 Pcs
  • DC Adaptor AP-9VA

 

 


Lutron DW-6090A Datasheet


Produk asli Kami distributor langsung Lutron Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya Indonesia.