The HI98192 is supplied with the HI763133 four-ring conductivity probe with a built-in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.
Produk asli Kami distributor langsung Hanna Harga murah. Pengiriman ke seluruh Indonesia.
Whatsapp : 0821 3010 0456
Email : [email protected]
CV. Syariftama Multi Global has a wide range of Hanna products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
The HI-98192 is a waterproof, portable conductivity meter that has an expanded conductivity range from 0.000µS/cm to 400 mS/cm, as well as TDS, resistivity and three salinity scales. This meter automatically recognises the probe type (two or four ring) and allows the user to adjust the nominal cell constant.
HI-98192 is also ready to perform all three stages USP <645> method required for EC measurement of ultrapure water. Choose from seven memorised standards and obtain up to a five point conductivity calibration. For salinity (% range), HI-7037 standard allows users to make a one point calibration.
EC and TDS measurements are fully customisable and include: cell constant selection between 0.010 and 10.000, selection of linear or natural water (non-linear) or no temperature compensation (for actual conductivity reading), configurable temperature compensation coefficient range from 0.00 to 10.00%/°C, choice of reference temperatures of 15°C, 20°C and 25°C, and a selectable TDS factor between 0.40 and 1.00.
The HI-763123 four ring Stainless Steel conductivity probe features a quick connect DIN connector to make attaching and removing the probe simple and easy.
The HI-98192 allows storage of up to 400 log-on-demand samples or 1000 lot logging samples that can be later transferred to a PC with the supplied HI-920015 USB cable and HI-92000 software.
Comprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including date, time and calibration values are stored for retrieval at a later time.
The HI-98192 features a backlit graphic LCD with on-screen help. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.
The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes.
The HI-763133 four-ring stainless steel conductivity probe features a quick connect DIN connector to make attaching and removing the probe simple and easy.
Logged data can be transferred to a Windows compatible PC with the included HI-920015 micro USB cable and HI-92000 software.
Choose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI-7037 standard allows users to perform a one point calibration.
HI-98192 can be used to perform all three stages of USP method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.
Three stages of conformity:
On-screen guide:
Progress bar:
EC and TDS measurements are fully customizable and include: cell constant selection between 0.010 and 10.000, selection of linear or natural water (nonlinear) or no temperature compensation (for actual conductivity reading), configurable temperature compensation coefficient range from 0.00 to 10.00%/°C, choice of reference temperatures of 15°C, 20°C and 25°C, and a selectable TDS factor between 0.40 and 1.00. Ten sets of customized measurement parameters can be stored as a user profile and later recalled.
Pressing AutoHold during measurement will automatically hold the first stable reading on the display.
Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.
SKU | HI98192 |
---|---|
Product Name | Waterproof Portable EC/TDS/Resistivity/Salinity Meter – HI98192 |
Quote Required | Yes |
EC Range | 0.000 to 9.999 μS/cm*; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm) |
EC Resolution | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
EC Accuracy | ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater) |
EC Calibration | automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) |
TDS Range | 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L) |
TDS Resolution | 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L) |
TDS Accuracy | ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater) |
EC/TDS Temperature Compensation | noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F) |
Temperature Correction Coefficient | 0.00 to 10.00 %/°C |
EC to TDS Conversion Factor | 0.40 to 1.00 |
Reference Temperature | 15°C, 20°C and 25°C |
EC/TDS Multi-range Measurement Modes | autorange, autoend, lock and fixed range |
Salinity (% NaCl) Range | 0.0 to 400.0% |
Salinity (% NaCl) Resolution | 0.1% |
Salinity (% NaCl) Accuracy | ±1% of reading |
Salinity (% NaCl) Calibration | max. one point only in % range (with HI7037 standard) |
Salinity (PSU) Range | 0.00 to 42.00 (PSU) |
Salinity (PSU) Resolution | 0.01 PSU |
Salinity (PSU) Accuracy | ±1% of reading |
Salinity (PSU) Calibration | based on conductivity calibration |
Salinity Range | 0.00 to 80.00 (ppt) |
Salinity Resolution (ppt) | 0.01 ppt |
Salinity Accuracy (ppt) | ±1% of reading |
Salinity Calibration (ppt) | based on conductivity calibration |
Resistivity Range | 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm |
Resistivity Resolution | 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm* |
Resistivity Accuracy | ±1% of reading (±10 Ω or 1 digit, whichever is greater) |
Temperature Range | -20.0 to 120.0°C (-4.0 to 248.0°F) |
Temperature Resolution | 0.1°C (0.1°F) |
Temperature Accuracy | ±0.2°C; ±0.4°F (excluding probe error) |
EC/TDS Probe | HI763133, four ring conductivity/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included) |
Logging Type | Log-on-demand |
Logging Memory | up to 10 |
Connectivity | opto-isolated USB with optional HI 92000 software and micro USB cable |
Automatic Shut-Off | user selectable |
Battery Type/Life | 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight |
Environment | 0 to 50°C (32 to 122°F); RH 100% (IP67) |
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
Weight | 400 g (14.2 oz.) |
Ordering Information | HI98192 is supplied with HI763133 conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. |
Notes | *The 0.001 μS/cm EC range and 0.1 MΩ•cm not available with supplied probe |
Produk asli Kami distributor langsung Hanna Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya Indonesia.
CV. Syariftama Global Indonesia berdiri sejak tahun 2017 merupakan online store yang menyediakan GPS, Alat Ukur & Alat Lab, Survey Pemetaan, Komunikasi dan Drone. Silahkan berbelanja dengan aman dan nyaman. Anda juga bisa langsung datang ke toko kami.