The HI-96742 portable photometer is for the measurement of low range iron and low range manganese. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration.
Produk asli Kami distributor langsung Hanna Harga murah. Pengiriman ke seluruh Indonesia.
Whatsapp : 0821 3010 0456
Email : [email protected]
CV. Syariftama Multi Global has a wide range of Hanna products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
The HI-96742 portable photometer is for the measurement of low range iron and low range manganese. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time.
The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
CAL Check™
Features at-a-glance
Built in timer
Indexing indent on meter
Cooling Lamp Indicator
Error messages
Auto-shut off
Battery status indicator
The instrument has a battery level indicator to display reaming life as follows:
Units of measure – Appropriate unit of measure is displayed along with reading.
Iron is naturally present in water in low concentrations, but it reaches high concentrations in wastewater effluents. The iron concentration in water needs to be monitored because it becomes harmful above certain levels. In domestic water, for instance, iron can unpleasantly alter the taste, stain laundry, damage kitchenware and favor the growth of certain bacteria. Iron is also an indicator of ongoing corrosion in water cooling and heating systems.
Moreover, iron is normally monitored in mining wastewater to avoid contamination. Manganese is one of the most common metals present in nature and is used in many industrial applications, for example, the production of fertilizers and in the pharmaceutical industry. Manganese salts are also used in iron alloys (steel manufacturing) and non-iron alloys as it improves their corrosion resistance and hardness. Manganese, in high concentrations, can produce corrosion and scaling in pipes, which is a serious industrial concern.
The HI96742 offers multiple methods within one meter. Iron determination uses an adaptation of the TPTZ method and manganese determination uses an adaptation of the 1-(2-pyridylazo)-2-naphthol PAN method. The reagents are in powder and liquid form depending on the parameter being tested. When the appropriate reagent is added to the sample, it will display a color change; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law.
This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For determination of low range iron and low range manganese a narrow band interference filter at 525 nm (green) allows only green light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.
The CAL Check™ standards are used for calibration and performance verification of photometers with the CAL Check™ function. Individual sets of CAL Check™ standards are available for each parameter on the HI96742:
Supplied with Certificate of Analysis
Provided storage containers
SKU | HI96742 |
---|---|
Product Name | Iron Low Range and Manganese Low Range Portable Photometer – HI96742 |
Quote Required | Yes |
Iron Range | 0.00 to 1.60 mg/L |
Iron Resolution | 0.01 mg/L |
Iron Accuracy | ±0.01 mg/L ±8% of reading @ 25°C |
Iron Method | Adaptation of the TPTZ method. The reaction between iron and the reagent causes a violet tint in the sample. |
Manganese Range | 0 to 300 μ/L |
Manganese Resolution | 1 μg/L |
Manganese Accuracy | ±2 μg/L ±3% of reading @ 25°C |
Manganese Method | Adaptation of the PAN Method. The reaction between manganese and the reagents causes an orange tint in the sample. |
Photometer/Colorimeter Light Source | Tungsten lamp |
Photometer/Colorimeter Light Detector | Silicon Photocell with narrow band interference filter @ 525 nm |
Display | Liquid Crystal Display (LCD) |
Battery Type/Life | 9V battery |
Automatic Shut-Off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 360 g (12.7 oz.) |
Dimensions | 192x104x69mm (7.6×4.1×2.7”) |
Ordering Information | HI96742 is supplied with two sample cuvettes with caps, 9V battery, instrument quality certificate, and instruction manual. |