Tanya via WhatsApp

Hanna HI-9126 Waterproof pH/ORP Meter with CalCheck

Share on facebook
Share on twitter
Share on linkedin
Hanna HI-9126 Waterproof pH/ORP Meter with CalCheck

Hanna HI-9126 Waterproof pH/ORP Meter with CalCheck

The HI-9126 portable pH/ORP includes Hanna’s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH electrode, Calibration Check™ warns users that maintenance may be needed.

 


Produk asli Kami distributor langsung Hanna Harga murah. Pengiriman ke seluruh Indonesia.


Whatsapp :  0821 3010 0456
Email : [email protected]

 

Hanna HI-9126 Waterproof pH/ORP Meter with CalCheck

CV. Syariftama Multi Global has a wide range of Hanna products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

The HI-9126 portable pH/ORP includes Hanna’s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH electrode, Calibration Check™ warns users that maintenance may be needed.

Key features

  • pH Calibration Check™
  • Electrode condition monitoring
  • Measurement store and recall
  • Backlit, multi-level LCD display
  • User-selectable calibration reminder
  • Tutorial messages displayed on LCD
  • BEPS; (Battery Error Prevention System)

Supplied with

  • HI-1230B pH electrode and HI 7662 temperature probe
  • Starter pack of cleaning and buffer solutions
  • 100 mL plastic beaker
  • Batteries, instructions and hard carrying case

Specifications Hanna HI-9126 Waterproof pH/ORP Meter with CalCheck :

Range – pH -2.00 to 16.00 pH
  ORP ±699.9 mV; ±1999 mV
 Temperature -20.0 to 120.0°C / -4.0°F to 248.0°F
Resolution – pH 0.01 pH
 ORP 0.1 mV; 1 mV
 Temperature 0.1°C / 0.1 °F
Accuracy @ 20°C – pH ±0.01 pH
 ORP ±0.2 mV; ±1 mV
 Temperature ±0.4°C/±0.8°F (excluding probe error)
pH Calibration Check yes, check the electrode status during calibration
Calibration – pH automatic, one or two point with seven memorised buffer values (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers
 offset ±1 pH
 Slope from 80 to 108%
Temperature Compensation automatic or manual, -20 to 120°C (-4 to 248°F) without temperature probe
pH Electrode HI-1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included)
Temperature Probe HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included)
Input Impedance 1012 Ohms
Battery Type / Life 1.5V (3) AAA / approximately 200 hours of continuous use without backlight (50 hours with backlight). auto-off after 20 minutes of non-use (can be disabled)
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)
Weight 300 g (10.6 oz.)

 

 


Hanna HI-9126 Datasheet


Produk asli Kami distributor langsung Hanna Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya Indonesia.

Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.

 