Tanya via WhatsApp

Fluke i2500-18 iFlex® Flexible Current Probes

Share on facebook
Share on twitter
Share on linkedin
Fluke i2500-18 iFlex® Flexible Current Probes

Fluke i2500-18 iFlex® Flexible Current Probes

  • Expands the Measurement Range to 2500 A AC while Providing Increased Display Flexibility, Ability to Measure Awkward Sized Conductors and Improved Wire Access
  • CAT IV 600 V, CAT III 1000 V
  • 7.5 mm Coil Diameter Allows Measurement in Tight Spaces
  • Ergonomic Design Allows Easy Operation with One Hand
  • 1.8 m (6 ft) Cable

 


Produk asli Kami distributor langsung Fluke Harga murah. Pengiriman ke seluruh Indonesia.


Whatsapp :  0821 3010 0456
Email : [email protected]

 

Fluke i2500-18 iFlex® Flexible Current Probes

CV. Syariftama Multi Global has a wide range of Fluke products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

The Fluke iFlex® flexible current probes expand the measurement range of the select Fluke meters to 2500 A AC while providing the ultimate measurement flexibility. The iFlex® probes connect directly to the meter, displaying current measurements without error prone scaling factors. The 1.8 m (6 ft) cord allows separation between the measurement location and the clamp meter making it easier to view the display. The large loop size and thin cross section allow measurement of awkward sized conductors and improved wire access in crowded spaces. Available in 25 cm (10 in) and 45 cm (18 in) sizes.

Fitur Fluke i2500-18 iFlex® Flexible Current Probes :

  • Expands the Measurement Range to 2500 A AC while Providing Increased Display Flexibility, Ability to Measure Awkward Sized Conductors and Improved Wire Access
  • CAT IV 600 V, CAT III 1000 V
  • 7.5 mm Coil Diameter Allows Measurement in Tight Spaces
  • Ergonomic Design Allows Easy Operation with One Hand
  • 1.8 m (6 ft) Cable

Spesifikasi Fluke i2500-18 iFlex® Flexible Current Probes :

Specifications
Range Resolution Accuracy
AC Current1 2500 A 0.1 A 3% ± 5 digits2
Frequency1 500 Hz 0.1 Hz 0.5% ± 5 digits
External magnetic field rejection
(with cable >10 cm from the coupling)
40 dB
Inrush1
Safety rating CAT III 1000 V, CAT IV 600 V
1. When used with compatible Fluke meter. Accuracy stated includes probe and meter accuracy.
2. For position accuracy at non-optimum positions, see Position sensitivity specifications table “A”
Position Sensitivity Specifications
Distance from Optimum i2500-18 Additional iFlex® Error
A 1.4 in (35.6 mm) ±0.5%
B 2.0 in (50.8 mm) ±1.0%
C 2.5 in (63.5 mm) ±2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating

 

 


Fluke i2500-18 Datasheet


Produk asli Kami distributor langsung Fluke Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya Indonesia.