Fluke 43 is a single phase power quality analyzer which combines the most useful capabilities of a power quality analyzer, multimeter and scope. It measures power harmonics, captures voltage sags, transients and inrush current. The Fluke 43’s monitoring functions help track intermittent problems and power system performance.
The Fluke 43 Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems and diagnose equipment failures.
Technical Data | |
Input Characteristics | Input impedance: 1 MW, 20 pF Voltage Rating: 600V rms, CAT III |
Volt/Amps/Hertz Display | True-rms voltage (ac+dc) Ranges: 5.000V, 50.00V, 500.0V, 1250V* Accuracy: ±(1% +10 counts) True-rms current (ac + dc) Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy: ±(1% +10 counts) Mains frequency Ranges: 40.0 to 70.0 Hz Accuracy: ±(0.5% +2 counts) |
Power Display | Watts, VA, VAR Ranges: 250 W, 2.50 kW, 25.0 kW, 250 kW, 2.50 MW, 250 MW Accuracy: ±(4% + 4 counts) Power Factor, PF Displacement Power Factor, DPF Range: 0.00 to 0.25 Accuracy: Not specified Range: 0.25 to 1.0 Accuracy: ±0.04 |
Harmonics Display | Voltage Ranges: 1st to 51st harmonic Accuracy: ±(3% +2 counts) to ±(15% +5 counts) Current Ranges: 1st to 51st harmonic Accuracy: ±(3% +8 counts) to ±(5% +8 counts) Power Ranges: 1st to 51st harmonic Accuracy: ±(5% +2 counts) to ±(30% +5 counts) Line frequency Ranges: 40 Hz to 70 Hz fundamental Accuracy: ±0.25 Hz Phase Ranges: 2nd to 51st harmonic Accuracy: ±3 º to ±15 º K-factor Ranges: 1.0 to 30.0 Accuracy: ±10% |
Sags and Swells Recording | Recording times: 4 min to 16 days (selectable) True-rms voltage: Ranges: 5.000V, 50.00V, 500.0V, 1250V* Accuracy: ±(2% +10 counts) True-rms current Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy: ±(2% +10 counts) |
Other Recording | Recording times: 4 min to 16 days (selectable) Parameters: Choose up to two from one of the groups below V/A/Hz: Line voltage, current, frequency Power: Watts, VA, VAR, PF, DPF, frequency Harmonics: THD, harmonic voltage, (or current, or power), frequency, % of total, phase Ohms: Ohms, diode, continuity, capacitance Temperature: Temperature Scope: DC voltage, dc current, ac voltage, ac current, frequency, pulse width, phase, duty cycle, peak max, peak min, peak min-max, crest factor |
Transient Capture | Minimum pulse width: 40 ns Voltage threshold settings: 20%, 50%, 100%, 200% above or below normal voltage Min voltage and max voltage at cursor: Ranges: 10V, 25V, 50V, 125V, 250V, 500V, 1250V Accuracy: ±5% of full scale |
Inrush Capture | Current ranges: Ranges: 1A, 5A, 10A, 50A, 100A, 500A, 1000A Inrush times: Ranges: 1s, 5s, 10s, 50s, 100s, 5 min Cursor readings, Current at cursor Ranges: 12.5A, 25A, 50A, 125A, 250A, 500A, 1250A, 2500A, 5 kA Accuracy: ±5% of full scale Time between cursors Ranges: 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels) |
Scope Display | Time ranges: Ranges: 20 ns/div to 60 s/div Max sampling rate: Ranges: 25 MS/s Bandwidth: Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads Current channel [2]: 15 kHz at inputs, 10 kHz with 80i-500s Probe Coupling: AC, DC Vertical sensitivity: Ranges: 5 mV/div to 500V/div Vertical resolution: 8 bit (256 levels) Record length: 512 samples per channel Timebase modes: Normal, roll, single Pre-trigger: Up to 10 divisions Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor |
Ohms, Diode,Continuity | Ohms: Ranges: 500.0W, 5.000 kW, 50.00 kW, 500.0 kW, 5.000 MW, 30.00 MW Accuracy: ±(0.6% +5 counts) Diode voltage: Accuracy: ±(2% +5 counts) Continuity: Beeper on at < (30W ±¤5W) Max current: 0.5 mA Capacitance: Ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF Accuracy: ±(2% +10 counts) Temperature** Ranges: -100.0 ºC to 400.0 ºC, -200.0 ºF to 800.0 ºF Accuracy: ±(0.5% +5 counts) |
Screen Memories | 10 |
Optically Isolated RS-232 Interface | To printer: Supports HP Laserjet®, Deskjet®, Epson FX/LQ and Postscript printers with optional PAC91 Printer Adapter Cable To PC: FlukeView® Power Quality Analyzer Software included |
FlukeView Power Quality Software | Hardware requirements: PC or 100% compatible with Windows® 3.1, Windows® 95, or Windows NT® . Enough RAM for Windows operating system. 4 MB hard drive space. Pointing device (mouse) recommended. |