Ultrasonic Scanner A2075 SoNet Flaw Detector

  • Velocity 3020 m/s
  • Operating frequency 0.5 MHz
  • Range of the calibrated amplifier 0-40 dB
  • Limit of the acceptable basic absolute accuracy in measuring of the coordinates of the flaws along the circumference of the pipe, not more than ±100 mm
  • Limit of the acceptable basic absolute accuracy in measuring of the coordinates of the flaws towards the pipe, not more than ±20 mm

 


Produk asli Kami distributor langsung Acoustic Control Systems (ACS) Harga murah. Pengiriman ke seluruh Indonesia.


Whatsapp :  0851 6306 9421
Email : [email protected]

Ultrasonic Scanner A2075 SoNet Flaw Detector

CV. Syariftama Multi Global has a wide range of Acoustic Control Systems (ACS) products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

Noncontact ultrasonic scanner-flaw detector А2075 SoNet is applicable for automatic flaws search in the metal pipe’s walls of 1020 ÷ 1420 mm in diameter and with thickness starting from 6mm. Detection of a stress-corrosion and corrosion flaws in the pipe’s body. Detection of flaws in flats (sheet products) with indication of flaw’s quantity, relative dimensions and locations (coordinates). Noncontact ultrasonic scanner-flaw detector А2075 is applicable for automatic flaws search in the metal pipe’s walls of 1020 ÷ 1420 mm in diameter and with thickness starting from 6mm.

Wi-Fi connection between the PC and the scanner-flaw detector provides a great mobility and the possibility for the operator to conduct testing remotely.

An image of a pipe section is made right during the scanning that helps to estimate the flaws found and helps to decide if an additional inspection with the other NDT methods is necessary.

Continuing documentation of the results as a scanning image of the pipe.

Efficient review of the collected scan images in the screen of the Notebook.

Post-processing of the scan images along with recording of the location, orientation and the type of the flaws.
Time required to set up the instrument and start inspection is just 3 minutes.

The possibility to upload the data from intratubal inspection and attach it to the main report.

Block structure of the instrument makes it possible to promptly replace a broken blocks on-the-site by only one operator.

Portability – the scanner – flaw detector can be carried by 2 people and can be operated by 1 user.

A2075 SONET

Application

Mainly the instrument is used as a part of flaw detection sets. Such flaw detection sets are used for searching flaws in gas pipelines, oil pipelines and products pipe line during major repairs or during the construction process.

Scanner-flaw detector А2075 SoNet is able to successfully detect both types of flaws: stress-corrosion flaws and other surface or internal flaws of the pipe.

The inspection is conducted by an inline automatic moving of the inspecting part of a flaw detector along generatrix on the external surface of a pipe. During the inspection full circle flaw detection is held. An image of a pipe section is made right during the scanning that helps to estimate the flaws found, to plot the coordinates, to estimate their type and shape, using standard tools of nondestructive testing.

Productivity – up to 7 meters of pipe per minute.

High sensitivity – detection stress-corrosion flaws and corrosion from 1mm.

Scanner flaw-detection is able to work on the pipe that has been earlier shelled from the old isolation. The scanner ensures 100% recurrence of the data.

Specifications Ultrasonic Scanner A2075 SoNet Flaw Detector

Velocity 3020 m/s
Operating frequency 0.5 MHz
Range of the calibrated amplifier 0-40 dB
Limit of the acceptable basic absolute accuracy in measuring of the coordinates of the flaws along the circumference of the pipe, not more than ±100 mm
Limit of the acceptable basic absolute accuracy in measuring of the coordinates of the flaws towards the pipe, not more than ±20 mm
Maximum sensitivity of the receiver, not less than 20 mKV
Measurement accuracy of the amplitude ratio of signals at the receiver input, not more than ±1 dB
Power Accumulator blocks
Voltage 12 V
Operating time (accumulator) 8 h
Weight 42 kg
Average error-free running time 30000 hours
Average lifetime, not less than 4 years
Operation conditions: air temperature from -40 to +50°C
relative air humidity at a temperature of +35 °С, not more than 95%
Dimensions 407 х 655 х 407 mm

Delivery Kit Ultrasonic Scanner A2075

  • PC-Panasonic Toughbook CF-U1
  • Charging unit with cable for PC
  • Receiver-transmitter unit (RTU)
  • Transfer platform
  • Block of the electro-magnetic acoustic transducer
  • Transportation packing for scanning device
  • Transportation packing for RTU, PC and spare parts
  • Passport (can be sent by e-mail)
  • Operation manual (can be sent by e-mail)
  • The standard (technique) of ultrasonic testing of a pipe’s base metal with the non-contact ultrasonic scanner-flaw detector A2075 SoNet (can be sent by e-mail)
  • CD with the documents and Software( items can be sent by e-mail)

List Of Spare Part And Tools

  • Inductor of the electro-magnetic acoustic transducer (3 items)
  • General-purpose tester
  • Cross screwdriver
  • Flat-blade screwdriver
  • Set of Allen keys
  • Allen key for the encoder

Additionally

  • Charging unit with cable for accumulator unit of (RTU)
  • Accumulator for PC
  • Field magnet of the electro-magnetic acoustic transducer

 

 


Produk asli Kami distributor langsung Acoustic Control Systems (ACS). Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya Indonesia.

Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.

CEK JUGA YANG INI

BUAT PERMINTAAN HARGA