The HI96708 portable photometer is for the measurement of nitrite in a wide variety of water samples. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
Produk asli Kami distributor langsung Hanna Harga murah. Pengiriman ke seluruh Indonesia.
Whatsapp : 0821 3010 0456
Email : [email protected]
CV. Syariftama Multi Global has a wide range of Hanna products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
The HI96708 portable photometer is for the measurement of nitrite in a wide variety of water samples. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
CAL Check™– Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.
GLP – Records the date of the last user calibration performed.
Built in timer – Allows the use of a timer to ensure the appropriate 3 minutes and 30 seconds reaction time is used for the chemical reaction. At the end of the timer countdown the meter will automatically take the reading. This feature ensures consistency across multiple users.
Indexing indent on meter – The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.
Cooling Lamp Indicator – It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.
Error messages – Messages on display alerting to problems including no cap, over range and under range readings, and light source error.
Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.
Battery status indicator
Units of measure – Appropriate unit of measure is displayed along with reading.
Nitrites can be harmful to aquatic organisms even in low concentrations and for this reason, they are closely monitored in aquaculture facilities. In cooling towers, however, an adequate amount of nitrites is necessary to prevent corrosion. In high concentrations, they can be harmful to the environment and to humans. They are, therefore, normally monitored to verify the quality of water for domestic use, as well as lakes and ponds.
Nitrites are an intermediate product in the nitrogen cycle and are produced by ammonia oxidation with water, or even originate in industrial waste directly. They must not be present in drinking water.
The HI96708 uses an adaptation of the Ferrous Sulfate method to measure nitrite concentrations in the 0 to 150 mg/L (ppm) range. When the reagent is added to samples containing nitrite, the sample will turn a greenish-brown; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complimentary color, and the emitted radiation is dependent upon concentration. For higher levels of nitrite, a narrow band interference filter at 575 nm (yellow-green) allows only yellow-green light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.
*Reagents ordered separately
The HI96708-11 CAL Check™standards are used for calibration and performance verification of photometers with the CAL Check™ function.
Supplied with Certificate of Analysis
Provided storage containers
SKU | HI96708-web |
---|---|
Product Name | Nitrite High Range Portable Photometer – HI96708 |
Quote Required | Yes |
Nitrite Range | 0 to 150 mg/L (ppm) |
Nitrite Resolution | 1 mg/L |
Nitrite Accuracy | ±4 mg/L ±4% of reading |
Nitrite Method | adaptation of the Ferrous Sulfate method |
Photometer/Colorimeter Light Source | tungsten lamp |
Photometer/Colorimeter Light Detector | silicon photocell with narrow band interference filter @ 575 nm |
Battery Type/Life | 9V battery |
Automatic Shut-Off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 360g (12.7oz.) |
Dimensions | 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
Ordering Information | HI96708 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual. |